Regulation AGV When water temperature will reach the set size silfon
through system of transfers influences the valve which blocks gas access to the
basic torch. At decrease in water temperature system the thermocylinder - a temperature
regulator is opened by the valve and the basic torch is lighted from burning kindleà.
Automatics of safety consisting of the electromagnetic valve, the thermocouple
to kindleà, works the same as has been described above. For water heater start-up in work it is necessary to check up, whether it
is filled by water. For this purpose it is enough to open any of water folding
hot water and to be convinced that water follows from it under a pressure. Then
open the crane on a gas pipeline in front of the device, having opened a door,
bring the lighted match to kindleó and open its crane. Through 1-2
mines has eaten ignitions it is necessary to delay the electromagnet button down
to refusal, thus the button should remain in the bottom position. Having convinced
by that kindle burns, to open the crane of the basic torch which should be lighted.
If the torch does not light up, and Kindle will go out, repeated ignition can
be made only after aeration of a fire chamber within 2-3 minutes After water heater
start-up it is necessary to close doors and to check up depression presence in
a flue the lighted match. At absence depression in a flue, and also at gases from
a fire chamber to use a water heater categorically it is forbidden.
After
heating of water to the established temperature the temperature regulator stops
gas giving to the basic torch. At water temperature drop in a water heater on
5-10 °Cas a result of selection of hot water or òåïëîïîòåðü at heating the temperature
regulator renews gas giving to the basic torch. The maximum water temperature
is established by rotation of the right bottom nut automatics blocks. For rise
in temperature the nut needs to be turned downwards, and for fall - upwards. For
water heater deenergizing it is necessary to close the crane kindleà and the crane
of the basic torch, and also the crane on a gas pipeline in front of the device. Water heaters are served by the experts acquainted with the instruction
and key rules of safety precautions.
|